The Dual Priority Switch Monitor is designed to monitor the state of one or more single-pole, volt-free contacts connected on a single pair of cables on two separate circuits
S21 Dual Priority Switch Monitor
Distributed Architecture
Highly Survivable
The S21 Dual Priority Switch Monitor Module (IOM2103) is an addressable dual priority interrupt switch monitor that is a means of connecting and identifying two conventional monitor point circuits at the main FxIP fire control system. IOM2103 switch monitors connect to the SLC, are programmed via an 8 pin DIL switch (1-7 for addressing, 8 for Class A/B) and are used to monitor one or two Class A or B (Style D or B) circuits.
IOM2103 – Dual Priority Switch Monitor Module
- Dual Class A/B Input Circuits on a single address
- Monitors dry contact devices
- Priority interrupt feature for fast response
- Dual LED’s visible through the fascia plate label
- Field programmable
- Fully supervised
- Plate mounted for surface/flush mounting in 4” square boxes
- LED for polling/alarm annunciation
- DIL switch addressing
- RoHS Compliant
The contractor shall furnish and install, where indicated on the plans, addressable interface devices for the monitoring and supervision of contact type devices connected to the Fire Alarm control. The devices shall monitor one or two normally open dry contact circuits. The addressable interface devices shall communicate to the main fire control via the analog addressable circuit. The addressable interface device must be UL/ULC listed and UL/ULC listed as compatible with Harding network fire controls. The addressable interface device shall be Harding part number IOM2103.
- Dual Priority Switch Monitor
-
The S21 Dual Priority Switch Monitor Module (IOM2103) is an addressable dual priority interrupt switch monitor that is a means of connecting and identifying two conventional monitor point circuits at the main FxIP fire control system. IOM2103 switch monitors connect to the SLC, are programmed via an 8 pin DIL switch (1-7 for addressing, 8 for Class A/B) and are used to monitor one or two Class A or B (Style D or B) circuits.
IOM2103 – Dual Priority Switch Monitor Module
- Data Sheet
- Specs
-
- Dual Class A/B Input Circuits on a single address
- Monitors dry contact devices
- Priority interrupt feature for fast response
- Dual LED’s visible through the fascia plate label
- Field programmable
- Fully supervised
- Plate mounted for surface/flush mounting in 4” square boxes
- LED for polling/alarm annunciation
- DIL switch addressing
- RoHS Compliant
- Architects
-
The contractor shall furnish and install, where indicated on the plans, addressable interface devices for the monitoring and supervision of contact type devices connected to the Fire Alarm control. The devices shall monitor one or two normally open dry contact circuits. The addressable interface devices shall communicate to the main fire control via the analog addressable circuit. The addressable interface device must be UL/ULC listed and UL/ULC listed as compatible with Harding network fire controls. The addressable interface device shall be Harding part number IOM2103.