The CCR provides the Alarm/Trouble/Supervisory Relays and The MLR provides for Masterbox or Line Reversal connections
Masterbox-Line Reversal
Distributed Architecture
Highly Survivable
The CCR3 provides for Common Alarm, Common Trouble and Common Supervisory relays (NO/CO/NC) activated by events anywhere on the fire control network. The three relays are rated at 2.0A @30 VDC Resistive load each.
The CCR3 can be mounted with any VPM or SDM installed on the network fire system by a simple ribbon cable connection. Multiple instances of the CCR3 may be installed as required on each display module installed on the network and up to two CCR3 boards may be daisy chained together off of any single network module. The CCR3 is mounted directly to the system chassis within the cabinet.
The MLR3 is also mounted with any display module installed on the network fire system by a simple ribbon cable connection. If present, the MLR3 may be daisy-chained directly off of the CCR3. The MLR3 is mounted directly to the system chassis within the cabinet.
- CCR3
- MLR3
- Common cards can be connected
to any FxIP™ distributed display
module (VPM/SDM3-IP) - Common cards may be daisy
chained up to two per networked
module - Common Control card (CCR3)
provides relays for Common
Alarm, Common Trouble and
Common Supervisory - CCR3 relays NO/CO/NC, rated at
2A @30VDC Resistive Load - MLR3 Masterbox/Line Reversal
Card - Simple ribbon cable connection
- Mounts directly onto cabinet
chassis - Green/RoHS Compliant
n/a
- CCR/MLR
-
The CCR3 provides for Common Alarm, Common Trouble and Common Supervisory relays (NO/CO/NC) activated by events anywhere on the fire control network. The three relays are rated at 2.0A @30 VDC Resistive load each.
The CCR3 can be mounted with any VPM or SDM installed on the network fire system by a simple ribbon cable connection. Multiple instances of the CCR3 may be installed as required on each display module installed on the network and up to two CCR3 boards may be daisy chained together off of any single network module. The CCR3 is mounted directly to the system chassis within the cabinet.
The MLR3 is also mounted with any display module installed on the network fire system by a simple ribbon cable connection. If present, the MLR3 may be daisy-chained directly off of the CCR3. The MLR3 is mounted directly to the system chassis within the cabinet.
- CCR3
- MLR3
- Data Sheet
- Specs
-
- Common cards can be connected
to any FxIP™ distributed display
module (VPM/SDM3-IP) - Common cards may be daisy
chained up to two per networked
module - Common Control card (CCR3)
provides relays for Common
Alarm, Common Trouble and
Common Supervisory - CCR3 relays NO/CO/NC, rated at
2A @30VDC Resistive Load - MLR3 Masterbox/Line Reversal
Card - Simple ribbon cable connection
- Mounts directly onto cabinet
chassis - Green/RoHS Compliant
- Common cards can be connected
- Architects
-