XPERT 8 Base

The XPERT 8 Base is a universal base that fits all detectors from the Soteria, Discovery and XP95 ranges.

Distributed Module Placement

All detectors in the Soteria®, Discovery® and XP95® range fit
into the XPERT 8 Intelligent Mounting Base. The base has a wide interior diameter for ease of access to cables and terminals. The ‘E-Z Fit’ feature allows you to fit the base screws, place the XPERT 8 Intelligent Mounting Base over the screws, slide it into place and tighten the screws. The detector requires a clockwise rotation into the base for fitting. Additionally the detector can be locked into the base for increased security, by a grubscrew using a 1.5mm hexagonal driver

Highly Survivable

  • Wide interior diameter for ease of access to cables and terminals
  • ‘E-Z Fit’ allows for simple mounting of the detector base after wiring
  • Isolated and non-isolated devices supported
  • Isolated wiper – maintains loop connectivity during temporary removal of devices

The XPERT 8 card, Part Number 38532-064, supplied with the base, has pre-punched pips to remove to set the address.

  • SA5000-200 – XPERT 8 Intelligent Mounting Base

Part Number Specifications For PC Boards:

AC-100P-1-AAA-BBB
 
P Paint Option Cabinet Color
AAA Module Slot 1

(lower slot)

– ALM3-IP-ai
– ESU3-IP

Addressable Loop Module (ALM3-IP)

–  Addressable Loops: a

–  IOC Circuits: i

Ethernet Switch Unit

BBB Module Slot 2

(upper slot)

– ALM3-IP-ai

Addressable Loop Module (ALM3-IP)

–  Addressable Loops: a

–  IOC Circuits: i

  ETP3 accommodation An ETP3 is included if either module slot contains an ALM3-IP

Available PC Boards:

MODEL NUMBER DESCRIPTION
ESU3-IP Ethernet Switch Unit (Unmanaged 8 port)
ALM3-IP-22 Addressable Loop Module (2 Loops, 2 Integral Outputs) c/w APU3
ALM3-IP-20 Addressable Loop Module (2 Loops, 0 Integral Outputs) c/w APU3
ALM3-IP-12 Addressable Loop Module (1 Loop, 2 Integral Outputs) c/w APU3
ALM3-IP-10 Addressable Loop Module (1 Loop, 0 Integral Outputs) c/w APU3
ALM3-IP-02 Addressable Loop Module (0 Loops, 2 Integral Outputs) c/w APU3
ETP3 Ethernet Transient Protection board (2 port)

Part Number Specifications For Fiber Switches:

AC-100P-2-ABC-DEF
P Paint Option Cabinet Color
ABC-DEF Ethernet Switch See below
  ETP3 accommodation Two ETP3 boards are included
  PTP3 accommodation A PTP3 is included

Available Fiber Switches:

MODEL NUMBER DESCRIPTION
EIS6-100T-FT2 Four-port 100BASE-TX/two-port 100BASE-FX (multimode) switch w/ST connectors
EIS6-100T-FCS2 Four-port 100BASE-TX/two-port 100BASE-FX (single-mode) switch w/SC connectors
ETP3 Two ETP3 modules are included
PTP3 One PTP3 module is included

The contractor shall furnish and install, where indicated on the plans, remotely located IP-Addressable SLC and NAC circuits to distribute fire alarm system processing power, to eliminate long wiring runs back to a centrally located control panel and to increase overall system survivability. Remote SLC and NAC circuit modules shall be fully incorporated into the FxIP Fire Control system by simple CAT 5 connection. Connections shall be fully supervised, transient protected and monitored for ground faults. The combination of the IP Module and AC-100 cabinet shall be UL/ULC listed and UL/ULC listed as compatible with the Harding network fire controls. The remote cabinet shall be Harding part number AC-100 and remote IP modules shall be Harding part number(s) ALM3-IP-10, ALM3-IP-02, ALM3-IP-12, ALM3-IP-22, ALM3-IP-20, ESU3-IP, EIS6-100T-FT, EIS6-100T-FCS, ETP3, PTP3.

About

The XPERT 8 card, Part Number 38532-064, supplied with the base, has pre-punched pips to remove to set the address.

  • SA5000-200 – XPERT 8 Intelligent Mounting Base
Data Sheet
Specs

Part Number Specifications For PC Boards:

AC-100P-1-AAA-BBB
 
P Paint Option Cabinet Color
AAA Module Slot 1

(lower slot)

– ALM3-IP-ai
– ESU3-IP

Addressable Loop Module (ALM3-IP)

–  Addressable Loops: a

–  IOC Circuits: i

Ethernet Switch Unit

BBB Module Slot 2

(upper slot)

– ALM3-IP-ai

Addressable Loop Module (ALM3-IP)

–  Addressable Loops: a

–  IOC Circuits: i

  ETP3 accommodation An ETP3 is included if either module slot contains an ALM3-IP

Available PC Boards:

MODEL NUMBER DESCRIPTION
ESU3-IP Ethernet Switch Unit (Unmanaged 8 port)
ALM3-IP-22 Addressable Loop Module (2 Loops, 2 Integral Outputs) c/w APU3
ALM3-IP-20 Addressable Loop Module (2 Loops, 0 Integral Outputs) c/w APU3
ALM3-IP-12 Addressable Loop Module (1 Loop, 2 Integral Outputs) c/w APU3
ALM3-IP-10 Addressable Loop Module (1 Loop, 0 Integral Outputs) c/w APU3
ALM3-IP-02 Addressable Loop Module (0 Loops, 2 Integral Outputs) c/w APU3
ETP3 Ethernet Transient Protection board (2 port)

Part Number Specifications For Fiber Switches:

AC-100P-2-ABC-DEF
P Paint Option Cabinet Color
ABC-DEF Ethernet Switch See below
  ETP3 accommodation Two ETP3 boards are included
  PTP3 accommodation A PTP3 is included

Available Fiber Switches:

MODEL NUMBER DESCRIPTION
EIS6-100T-FT2 Four-port 100BASE-TX/two-port 100BASE-FX (multimode) switch w/ST connectors
EIS6-100T-FCS2 Four-port 100BASE-TX/two-port 100BASE-FX (single-mode) switch w/SC connectors
ETP3 Two ETP3 modules are included
PTP3 One PTP3 module is included
Architects

The contractor shall furnish and install, where indicated on the plans, remotely located IP-Addressable SLC and NAC circuits to distribute fire alarm system processing power, to eliminate long wiring runs back to a centrally located control panel and to increase overall system survivability. Remote SLC and NAC circuit modules shall be fully incorporated into the FxIP Fire Control system by simple CAT 5 connection. Connections shall be fully supervised, transient protected and monitored for ground faults. The combination of the IP Module and AC-100 cabinet shall be UL/ULC listed and UL/ULC listed as compatible with the Harding network fire controls. The remote cabinet shall be Harding part number AC-100 and remote IP modules shall be Harding part number(s) ALM3-IP-10, ALM3-IP-02, ALM3-IP-12, ALM3-IP-22, ALM3-IP-20, ESU3-IP, EIS6-100T-FT, EIS6-100T-FCS, ETP3, PTP3.

Menu